SKU: 90968811258

Bovine α-GLA ELISA Kit

Sale price$178.57 Regular price$198.41
Save 10%

Pay in installments of $49.60 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 28 - Aug 2

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Bovine α-GLA ELISA KitProduct Specification Usage Sample Processing and Requirements 1. Serum: Place the whole blood specimen collected in a serum separator tube at room temperature for 2 hours or at 4C overnight, then centrifuge at 1000g for 20 minutes. Remove the supernatant and store it at 20C or 80C. However, repeated freezing and thawing should be avoided. 2. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Within 30 minutes of collection,

Product Specification

Usage

Sample Processing and Requirements


1.
Serum: Place the whole blood specimen collected in a serum separator tube at room temperature for 2 hours or at 4°C overnight, then centrifuge at 1000×g for 20 minutes.
Remove the supernatant and store it at -20°C or -80°C.
However, repeated freezing and thawing should be avoided.


2.
Plasma: Collect the specimen using EDTA or heparin as an anticoagulant.
Within 30 minutes of collection, centrifuge at 1000×g for 15 minutes at 2-8°C.
Remove the supernatant and test it.
Alternatively, store it at -20°C or -80°C.
However, repeated freezing and thawing should be avoided.


3.
Tissue Homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove any residual blood (lysed red blood cells in the homogenate will affect the measurement results).
Weigh the tissue and mince it.
Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS.
The specific volume can be adjusted according to experimental needs and recorded.
It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice.
To further lyse tissue cells, the homogenate can be sonicated or repeatedly freeze-thawed.
Finally, centrifuge the homogenate at 5000×g for 5-10 minutes.
Remove the supernatant for analysis.


4.
Cell culture supernatant or other biological specimens: Centrifuge at 1000×g for 20 minutes.
Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.


Note: Hemolysis of the specimen will affect the final test results, so hemolyzed specimens are not suitable for this test.


Reagent Preparation
After removing the kit from the refrigerator, allow it to equilibrate to room temperature before use.
Dilution of 20× Wash Buffer: Dilute 1:20 with distilled water, i.e., add 1 part 20× Wash Buffer to 19 parts distilled water.


Procedure
1.
Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 20 minutes.
Seal the remaining strips in a ziplock bag and return them to 4°C.


2.
Set up standard wells and sample wells.
Add 50 μL of standard solution of varying concentrations to each standard well.


3.
Add 50 μL of the sample to be tested to the sample wells; leave blank wells untouched.


4.
Add 100 μL of horseradish peroxidase (HRP)-labeled detection antibody to each standard and sample well, except for the blank well.
Seal the wells with sealing film and incubate at 37°C in a waterbath or incubator for 60 minutes.


5.
Discard the liquid, pat dry on absorbent paper, and fill each well with wash buffer (350 μL).
Let stand for 1 minute, then discard the wash buffer and pat dry on absorbent paper.
Repeat this process five times (a plate washer can also be used).


6.
Add 50 μL each of substrates A and B to each well and incubate at 37°C in the dark for 15 minutes.


7.
Add 50 μL of stop solution to each well.
Within 15 minutes, measure the OD value of each well at a wavelength of 450 nm.


Calculation of Experimental Results:
Using the OD value of the standard as the horizontal axis and the concentration of the standard as the vertical axis, plot a standard curve on graph paper or using relevant software.
Obtain a linear regression equation.
Substitute the OD value of the sample into the equation to calculate the sample concentration.



Standard Curve

Sensitivity The minimum detection concentration was less than 1.0 ng/mL.
Species Reactivity Bovine
Theory The kit uses a double-antibody one-step sandwich enzyme-linked immunosorbent assay (ELISA). Samples, standards, and HRP-labeled detection antibodies are added sequentially to microwells pre-coated with a bovine α-galactosidase (αGAL) capture antibody. The sample is incubated and thoroughly washed. The color is developed using the substrate TMB, which converts to blue under peroxidase catalysis and to yellow under acid. The intensity of the color is positively correlated with the amount of bovine α-galactosidase (αGAL) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Detection Type Used for in vitro quantitative detection of bovine α-galactosidase (αGAL) content in serum, plasma, tissue homogenate and related liquid samples.
Composition

Name

96 T

Remarks

Microwell enzyme plate

12 wells×8 strips

None

Standard product

0.3mL*6 tubes

None

Sample diluent

6mL

None

Detection antibody-HRP

10mL

None

20× wash buffer

25mL

Dilution according to the instructions

Substrate A

6mL

None

Substrate B

6mL

None

Stop solution

6mL

None

Seal film

2 sheets

None

Remarks:

1. The concentrations of the standard solutions are: 400, 200, 100, 50, 25, and 12.5 ng/mL.

2. After testing a large number of normal specimens, the normal concentration values of the specimens are all within the detection range provided by the kit. During the experiment, 50 μL of sample can be directly sampled. If some sample values exceed the maximum standard concentration, the sample can be appropriately diluted with sample diluent before the experiment.

General Notes

1. Strictly follow the specified incubation time and temperature to ensure accurate results. All reagents must reach room temperature (20-25°C) before use. Refrigerate reagents immediately after use.

2. Improper plate washing can lead to inaccurate results. Ensure that the liquid in the wells is as dry as possible before adding substrate. Do not allow the microwells to dry out during incubation.

3. Remove any residual liquid and fingerprints from the bottom of the plate, otherwise it will affect the OD value.

4. The substrate developer solution should be colorless or very light in color. Substrate solution that has turned blue should not be used.

5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.

6. Avoid direct exposure to strong light during storage and incubation.

7. Allow the sealed bag to equilibrate to room temperature before opening to prevent water droplets from condensing on the cold plate strips.

8. No reaction reagents should come into contact with bleaching solvents or the strong fumes emitted by bleaching solvents.

Any bleaching component will destroy the biological activity of the reagents in the kit.

9. Do not use expired products.

10. If there is a possibility of disease transmission, all samples should be managed properly and the samples and detection devices should be handled according to the prescribed procedures.

Storage Temp. Unopened test kit, sealed and stored at 2-8℃, valid for 6 months
Test Range 12.5 ng/mL – 400 ng/mL.
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 90968811258

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.4 ★★★★★
Based on 11 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
K
Verified Purchase
Kindle Customer
Birmingham, US
★★★★★ 5
Powerful!
Color: Lux Galaxy, Size: Rechargeable Z1 Motor Max
This thing is powerful and works great! I was hesitant about some of the negative reviews, but this is worth it so far. I use it every day and haven't charged it in the week that I've had it. Some people complained about turning it off.... It's not that hard. Just hold the button down for a second or two and it shuts off, no fuss. If you tap/press the button you'll cycle through the next speed and then off. I only use the first speed to make my protein shake and matcha. I feel like the high speed would just whip everything to pure foam! I'm hoping this lasts me a long time.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 5, 2026
M
Verified Purchase
Michael Beineke
Whiting, US
★★★★★ 5
WORTH YOUR MONEY IF YOUR SECOND GUESSING, DONT!
Color: Lux Alpha Black, Size: Rechargeable Z1 Motor Max, Color: Lux Alpha Black, Size: Rechargeable Z1 Motor Max
THIS IS THE BEST! High powered, EXCELLENT FOR PROTEIN DRINKS!!!! The quality is SOLID! Super easy to clean, frothing is a 10, easy to store. Great stability. Battery life seems good too! All around Best Buy! Worth your money.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 24, 2026
T
Verified Purchase
T-Rexx
San Leandro, US
★★★★★ 5
Quiet and Effective frother/mixer and Terrific Customer Service
Zulay Kitchen Powerful Milk Frother Wand We ordered two Zulay frother wands and after just several months of continuous usage one of the units stopped working and the other one was sporadically working, where sometimes it would run “full power” and at other times it was barely spinning or turning the beverage. I called Zulay and gave them my Amazon order number. After the Customer Service rep walked me through some minor things to check on the units she was also convinced that the units were probably defective. She had a replacement sent from Zulay along with a mini as a bonus for our troubles! And she had Amazon ship the other replacement unit. Both shipments arrived promptly within days and we have been using them for months now without any major issues. We use the units (the two “standard” wands) almost every day and they get used two to three times a day. They only take ten to twenty seconds to mix up cocoa powder, hot or cold. And the same goes for different protein powder shakes. What I especially like about these units is that there have been many times when I have had to use them off-hours, like between 5:00 and 6:00 AM. They are Whisper quiet so nobody gets disturbed. One generally can’t do this level of quiet stirring/mixing with a kitchen hand blender/mixer or shake blenders. These Zulay mixing units have really come in “handy” for us. We are very Grateful to Amazon for their prompt delivery, and especially to the Customer Service representative at Zulay for her help, and to Zulay for standing behind their products and providing us with terrific and prompt Customer Service! Thank you! Cheers! November 3, 2025
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 3, 2025
A
Verified Purchase
Alexandry De Jesus
Grantham, US
★★★★★ 4
Rechargeable reliable
Color: Lux Alpha Black, Size: Rechargeable Z1 Motor Max
Nice, very reliable and easy-to-use and clean
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 20, 2026
M
Verified Purchase
Mundy55
Cuba, US
★★★★★ 5
Great look and very powerful - consider what your wanting to froth/mix - may be too powerful
Color: Lux White, Size: Rechargeable Z1 Motor Max
It's a great frother - but more for large drinks. Very powerful, even on the low speed. I returned it because I want something to mix my collagen and creamer in my coffee. The first time I turned it on it shot half the coffee out of the cup - very powerful. It has a great look, sleek and fits easy in the hand - but for what I needed, two powerful. It would have been nice to have a fully adjustable speed wand like my replaceable battery powered frother.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 1, 2026

recommand products